IBM ibm_pittsburgh

IBM · Apache-2.0 Metriq · CC-BY-4.0 last capture 2026-04-17

ibm_pittsburgh is a 156-qubit IBM quantum computer.

On its latest calibration (17 April 2026), a typical two-qubit operation failed about 1 in 640, better than 97% of the 67 other devices in this record.

In Metriq's independent test (19 February 2026), a layer of operations across a 10-qubit chain failed about 1 in 370.

Every figure below is the device's latest measurement of that metric, with its own date and source. See how the whole field is progressing →

Best 2Q fidelity
IBM · Apache-2.0
0.999214
fails about 1 in 1,270

Success rate of the chip's single best pair of qubits. The best pair flatters the chip; the typical one matters more.

Better than 96% of 67 other devices with this measurement
Measured 2026-04-17
Median 2Q error
IBM · Apache-2.0
0.00156224
fails about 1 in 640

How often a typical two-qubit operation on this chip fails, from the vendor's own calibration.

Better than 97% of 67 other devices with this measurement
Measured 2026-04-17
Median T1 (µs)
IBM · Apache-2.0
298.97

How long a typical qubit holds its state before it decays, in microseconds. Longer leaves more time to compute.

Better than 93% of 69 other devices with this measurement
Measured 2026-04-17
Median T2 (µs)
IBM · Apache-2.0
317.1

How long a typical qubit keeps its delicate quantum phase, in microseconds.

Better than 97% of 69 other devices with this measurement
Measured 2026-04-17
Median readout error
IBM · Apache-2.0
0.0045166
fails about 1 in 220

How often reading a typical qubit's value at the end gives the wrong answer.

Better than 100% of 69 other devices with this measurement
Measured 2026-04-17
CLOPS
Metriq · CC-BY-4.0
358613

Circuit layers per second: how fast the machine gets through work, overheads included.

Better than 40% of 5 other devices with this measurement
Measured 2026-02-17
EPLG (error/layer)
Metriq · CC-BY-4.0
0.0027295
fails about 1 in 370

Metriq's independent test of a 10-qubit chain: how often a layer of two-qubit operations fails, measured end to end.

Better than 40% of 5 other devices with this measurement
Measured 2026-02-19
QFT accuracy
Metriq · CC-BY-4.0
0

How well the machine runs a small quantum Fourier transform benchmark: 1 is perfect, 0 is no better than noise.

Better than 0% of 10 other devices with this measurement
Measured 2026-02-09
QAOA approx. ratio
Metriq · CC-BY-4.0
0.569502

How much better than random guessing a simple optimisation algorithm does on this machine: 1 is perfect, 0 is no better than chance.

Better than 60% of 10 other devices with this measurement
Measured 2026-02-17
Qubits
IBM · Apache-2.0
156

Physical qubits on the device. More only helps if they are good enough to use together.

Measured 2026-04-17

History

Each point is one dated measurement (4 snapshots in total).

Qubits

Provenance

Source
IBM · Apache-2.0
Licence
Apache-2.0 · Qiskit fake backend calibration snapshot
Raw redistributable
yes
Captured
2026-04-17T09:46:32

Cite this page

@misc{provenova_ibm_ibm_pittsburgh,
  title        = {IBM ibm_pittsburgh — calibration & benchmark history},
  howpublished = {\url{https://provenova.net/hardware/ibm/ibm_pittsburgh}},
  publisher    = {Provenova},
  note         = {accessed 2026-11-19}
}

Compare with

vs iqm iqm_emerald 2 shared metrics vs iqm iqm_garnet 2 shared metrics vs origin wukong_72 2 shared metrics vs quantinuum h2-2 3 shared metrics vs rigetti cepheus-1-108q 3 shared metrics vs ibm ibm_aachen 5 shared metrics vs ibm ibm_algiers 5 shared metrics vs ibm ibm_auckland 5 shared metrics

Data: real IBM device calibration published in Qiskit's fake backends (Apache-2.0). Rankings on the live leaderboard.